Enerpac ST-121 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Nástroje Enerpac ST-121. Enerpac ST-121 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 12
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
L1717 Rev. A 09/95
IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. If any shipping damage is
found, notify carrier at once. Shipping damage is
NOT covered by warranty. The
carrier is responsible for all repair or replacement cost resulting from damage in
shipment.
INSIDE THIS INSTRUCTION SHEET
DESCRIPTION
These swing cylinders are designed to swing 9in a clockwise or
counter-clockwise direction. They can also be used in straight clamping
applications. Single-acting and double-acting swing cylinders are available.
Clamp arms are not supplied with cylinders. Clamp arms can be purchased
separately or made according to the specifications on page 11.
®
PRODUCTION AUTOMATION
Instruction Sheet
Swing Cylinders -- Imperial
Model Number Code
1 2 3 4 optional 5 6 optional
S = swing
cylinder
T = threaded body
U = upper flange
L = lower flange
R = right swing
L = left swing
S = straight
(no swing)
S = single-
acting
D = double-
acting
L = long
stroke
12 kN only
1 = 1,3 kN
2 = 2,2 kN
5 = 5,6 kN
12 = 11,6 kN
1 = imperial V = Viton
DESCRIPTION.....................................................1
SPECIFICATIONS...............................................2
PRELIMANARY INFORMATION ....................3
MOUNTING SPECIFICATIONS........................4
Mounting Threaded Body Cylinders..................4
Mounting Upper and Lower Flange Cylinders ..5
INSTALLATION..................................................6
Changing Plunger Rotation ................................6
Attaching Clamp Arm ........................................7
Arms for Upper Flange Body ............................ 7
Hydraulic Connections....................................... 8
Port Identification............................................... 8
OPERATION...................................................... 16
Vent Plug.......................................................... 16
Pressure and Flow Rate.................................... 16
MAINTENANCE............................................... 10
TROUBLESHOOTING ..................................... 10
CLAMP ARM MACHINING SPEC.S ............ 11
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - Swing Cylinders -- Imperial

L1717 Rev. A 09/95IMPORTANT RECEIVING INSTRUCTIONSVisually inspect all components for shipping damage. If any shipping damage isfound, notify carrier

Strany 2 - SPECIFICATIONS

MAINTENANCEMaintenance is required when wear or leakage is noticed. Occasionally inspect allcomponents to detect any problem requiring service and ma

Strany 3 - PRELIMINARY INFORMATION

CLAMP ARM MACHINING SPECIFICATIONSSee Pressure and Flow Rate on page 9 to correctly measure the arm length. Todetermine the maximum clamping force fo

Strany 4 - MOUNTING SPECIFICATIONS

AustraliaEnerpacBlock V, Unit 3Regents Park Estate391 Park RoadRegents Park NSW 2143Tel: (61) (2) 743-8988Fax:8232-674-7747Belgium, Holland

Strany 5 - A WARNING

SPECIFICATIONSOperating Specifications — Maximum Flow Rate ChartAlso see graphs on page 3.300 lb (1,3 kN) — Maximum Clamp Arm Length is 2.25" (57

Strany 6 - LEFT SWING

Clamping Force -v- Arm Length GraphsPRELIMINARY INFORMATIONIMPORTANT: Failure to read and follow these instructions may lead tosystem malfunction or

Strany 7 - Contact

MOUNTING SPECIFICATIONSMounting Threaded Body CylindersThreaded body cylinders can be threaded into a tapped hole, secured to the fixtureusing a mount

Strany 8 - Port Identification

Mounting Upper and Lower Flange CylindersA WARNINGThe fixture must be capable of withstanding 5,000 psi (350 bar) hydraulicworking pressure when the c

Strany 9 - OPERATION

INSTALLATIONThese Swing Cylinders are designed so that you can set the position of the clamparm after mounting the cylinder. If you need to change th

Strany 10 - TROUBLESHOOTING

Attaching Clamp Arm1. Remove the retaining ring from the top of the plunger.2. Slide the clamp arm downover the plunger and use apliers to push the re

Strany 11

INSTALLATION (continued)Hydraulic ConnectionsTo make port connections, install fittings rated for 5000 psi (350 bar).DO NOT use thread sealant. Seali

Strany 12 - As of October 10, 1995:

OPERATIONSwing cylinders rotate 90° during the first portion of the stroke, continuing withoutrotation for the final clamping stroke. The straight do

Příbuzné modely SL-121 | SU-121 |

Komentáře k této Příručce

Žádné komentáře